Degradation of repaired denture base materials in simulated oral fluid

Che Tong Lin, Sheng Yang Lee, T. Y. Tsai, De Rei Dong, Yung Hsun Shih

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

This in vitro study evaluates the degradation of repaired denture bases upon immersion in a simulated oral fluid. Denture base materials (Luciton 199®), after being repaired by Repair Material® and Triad®, using three different joint surface designs (butt, round and 45° bevel), were immersed onto 99.5 vol.% ethanol/water solution (with similar solubility parameter) for various amounts of time (0-72 h). The flexural loads of the six combination of groups were measured by the three-point bending tests using a universal testing machine. Acoustic emission (AE) during sample fracturing were processed using the MISTRA 2001 system. The fracture pattern and surface details of the interface were examined with a scanning electronic microscope (SEM). Data were analysed using three-way ANOVA and Tukey LSD tests. SEM micrographs of the fracture interface were used to differentiate the fracture mode. The flexural loads (2.72 ± 0.51 Kgf) of the round joint specimens were significantly higher (P <0.05) than those (butt: 1.66 ± 0.38 Kgf, 45° bevel: 1.93 ± 0.41 Kgf) of the other two designs. This corresponds to the microscopic examination in which more cohesive failure mode was found for the round joint group after storage. The flexural loads (2.54 ± 0.39 Kgf) of the specimens repaired with Triad® were significantly higher (P <0.05) than those (1.59 ± 0.40 Kgf) of specimens repaired with Repair Material®. Significant progressive reduction of the flexural load and/or AE signals of the specimens was noted in proportion to the length of time of the immersion in the simulated oral fluid. Mechanical strength of a denture base repaired with a round joint design and light-cured material is significantly higher after immersion in simulated oral fluid.

Original languageEnglish
Pages (from-to)190-198
Number of pages9
JournalJournal of Oral Rehabilitation
Volume27
Issue number3
Publication statusPublished - Mar 2000

Fingerprint

Denture Bases
Immersion
Joints
Acoustics
Lysergic Acid Diethylamide
Solubility
Analysis of Variance
Ethanol
Light
Water
Repair Material

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Degradation of repaired denture base materials in simulated oral fluid. / Lin, Che Tong; Lee, Sheng Yang; Tsai, T. Y.; Dong, De Rei; Shih, Yung Hsun.

In: Journal of Oral Rehabilitation, Vol. 27, No. 3, 03.2000, p. 190-198.

Research output: Contribution to journalArticle

@article{cf3a91a6e4d84e52815e7b866682d1af,
title = "Degradation of repaired denture base materials in simulated oral fluid",
abstract = "This in vitro study evaluates the degradation of repaired denture bases upon immersion in a simulated oral fluid. Denture base materials (Luciton 199{\circledR}), after being repaired by Repair Material{\circledR} and Triad{\circledR}, using three different joint surface designs (butt, round and 45° bevel), were immersed onto 99.5 vol.{\%} ethanol/water solution (with similar solubility parameter) for various amounts of time (0-72 h). The flexural loads of the six combination of groups were measured by the three-point bending tests using a universal testing machine. Acoustic emission (AE) during sample fracturing were processed using the MISTRA 2001 system. The fracture pattern and surface details of the interface were examined with a scanning electronic microscope (SEM). Data were analysed using three-way ANOVA and Tukey LSD tests. SEM micrographs of the fracture interface were used to differentiate the fracture mode. The flexural loads (2.72 ± 0.51 Kgf) of the round joint specimens were significantly higher (P <0.05) than those (butt: 1.66 ± 0.38 Kgf, 45° bevel: 1.93 ± 0.41 Kgf) of the other two designs. This corresponds to the microscopic examination in which more cohesive failure mode was found for the round joint group after storage. The flexural loads (2.54 ± 0.39 Kgf) of the specimens repaired with Triad{\circledR} were significantly higher (P <0.05) than those (1.59 ± 0.40 Kgf) of specimens repaired with Repair Material{\circledR}. Significant progressive reduction of the flexural load and/or AE signals of the specimens was noted in proportion to the length of time of the immersion in the simulated oral fluid. Mechanical strength of a denture base repaired with a round joint design and light-cured material is significantly higher after immersion in simulated oral fluid.",
author = "Lin, {Che Tong} and Lee, {Sheng Yang} and Tsai, {T. Y.} and Dong, {De Rei} and Shih, {Yung Hsun}",
year = "2000",
month = "3",
language = "English",
volume = "27",
pages = "190--198",
journal = "Journal of Oral Rehabilitation",
issn = "0305-182X",
publisher = "Wiley-Blackwell",
number = "3",

}

TY - JOUR

T1 - Degradation of repaired denture base materials in simulated oral fluid

AU - Lin, Che Tong

AU - Lee, Sheng Yang

AU - Tsai, T. Y.

AU - Dong, De Rei

AU - Shih, Yung Hsun

PY - 2000/3

Y1 - 2000/3

N2 - This in vitro study evaluates the degradation of repaired denture bases upon immersion in a simulated oral fluid. Denture base materials (Luciton 199®), after being repaired by Repair Material® and Triad®, using three different joint surface designs (butt, round and 45° bevel), were immersed onto 99.5 vol.% ethanol/water solution (with similar solubility parameter) for various amounts of time (0-72 h). The flexural loads of the six combination of groups were measured by the three-point bending tests using a universal testing machine. Acoustic emission (AE) during sample fracturing were processed using the MISTRA 2001 system. The fracture pattern and surface details of the interface were examined with a scanning electronic microscope (SEM). Data were analysed using three-way ANOVA and Tukey LSD tests. SEM micrographs of the fracture interface were used to differentiate the fracture mode. The flexural loads (2.72 ± 0.51 Kgf) of the round joint specimens were significantly higher (P <0.05) than those (butt: 1.66 ± 0.38 Kgf, 45° bevel: 1.93 ± 0.41 Kgf) of the other two designs. This corresponds to the microscopic examination in which more cohesive failure mode was found for the round joint group after storage. The flexural loads (2.54 ± 0.39 Kgf) of the specimens repaired with Triad® were significantly higher (P <0.05) than those (1.59 ± 0.40 Kgf) of specimens repaired with Repair Material®. Significant progressive reduction of the flexural load and/or AE signals of the specimens was noted in proportion to the length of time of the immersion in the simulated oral fluid. Mechanical strength of a denture base repaired with a round joint design and light-cured material is significantly higher after immersion in simulated oral fluid.

AB - This in vitro study evaluates the degradation of repaired denture bases upon immersion in a simulated oral fluid. Denture base materials (Luciton 199®), after being repaired by Repair Material® and Triad®, using three different joint surface designs (butt, round and 45° bevel), were immersed onto 99.5 vol.% ethanol/water solution (with similar solubility parameter) for various amounts of time (0-72 h). The flexural loads of the six combination of groups were measured by the three-point bending tests using a universal testing machine. Acoustic emission (AE) during sample fracturing were processed using the MISTRA 2001 system. The fracture pattern and surface details of the interface were examined with a scanning electronic microscope (SEM). Data were analysed using three-way ANOVA and Tukey LSD tests. SEM micrographs of the fracture interface were used to differentiate the fracture mode. The flexural loads (2.72 ± 0.51 Kgf) of the round joint specimens were significantly higher (P <0.05) than those (butt: 1.66 ± 0.38 Kgf, 45° bevel: 1.93 ± 0.41 Kgf) of the other two designs. This corresponds to the microscopic examination in which more cohesive failure mode was found for the round joint group after storage. The flexural loads (2.54 ± 0.39 Kgf) of the specimens repaired with Triad® were significantly higher (P <0.05) than those (1.59 ± 0.40 Kgf) of specimens repaired with Repair Material®. Significant progressive reduction of the flexural load and/or AE signals of the specimens was noted in proportion to the length of time of the immersion in the simulated oral fluid. Mechanical strength of a denture base repaired with a round joint design and light-cured material is significantly higher after immersion in simulated oral fluid.

UR - http://www.scopus.com/inward/record.url?scp=0034154175&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034154175&partnerID=8YFLogxK

M3 - Article

VL - 27

SP - 190

EP - 198

JO - Journal of Oral Rehabilitation

JF - Journal of Oral Rehabilitation

SN - 0305-182X

IS - 3

ER -