Abstract

Statement of problem Patients with obstructive sleep apnea may stop breathing momentarily during sleep because of a narrow upper respiratory tract. One of the main treatments for obstructive sleep apnea is continuous positive airway pressure. However, after long-term treatment, patients tend to complain about the leakage, inconvenience, and discomfort of the nasal mask. Purpose The purpose of the study was to develop customized cushions and compare the clinical performance of the customized cushion with the conventional one. Material and methods Each participant's face was replicated by using a 3-dimensional scanner and reverse-engineering technology, and computer numerical control techniques were used to design and manufacture customized cushions. Forty participants were randomly divided into 2 groups, a control group with conventional cushions and an experimental group with customized cushions. The saturation level of peripheral oxygen, apnea-hypopnea index, leakage data, and answers to a comfort questionnaire were examined. Results Customized and conventional cushions were compared with independent sampling t tests and relational analyses. A significant difference was found in the apnea-hypopnea index (P=.001) of participants with the customized cushion and those with the conventional cushion. Participants with the conventional cushion had a lower apnea-hypopnea index. The customized cushion applied less headgear force and fit better than the conventional cushion. The leakage volume, saturation of peripheral oxygen (SpO2), treatment compliance, and degree of comfort were not significantly different between the groups. Conclusions Customized nasal mask cushions fit better and reduce the force applied by the headgear. Participants using a customized cushion showed an improved apnea-hypopnea index.

Original languageEnglish
Pages (from-to)29-34.e1
JournalJournal of Prosthetic Dentistry
Volume113
Issue number1
DOIs
Publication statusPublished - Jan 1 2015

Fingerprint

Continuous Positive Airway Pressure
Obstructive Sleep Apnea
Apnea
Masks
Nose
Oxygen
Respiratory System
Sleep
Respiration
Therapeutics
Technology
Control Groups

ASJC Scopus subject areas

  • Oral Surgery

Cite this

Clinical verification of patients with obstructive sleep apnea provided with a customized cushion for continuous positive airway pressure. / Cheng, Yih Lin; Hsu, Ding Yang; Lee, Hsin Chien; Bien, Mauo Ying.

In: Journal of Prosthetic Dentistry, Vol. 113, No. 1, 01.01.2015, p. 29-34.e1.

Research output: Contribution to journalArticle

@article{43f8bfb28eb74fd9a43869f908a75abc,
title = "Clinical verification of patients with obstructive sleep apnea provided with a customized cushion for continuous positive airway pressure",
abstract = "Statement of problem Patients with obstructive sleep apnea may stop breathing momentarily during sleep because of a narrow upper respiratory tract. One of the main treatments for obstructive sleep apnea is continuous positive airway pressure. However, after long-term treatment, patients tend to complain about the leakage, inconvenience, and discomfort of the nasal mask. Purpose The purpose of the study was to develop customized cushions and compare the clinical performance of the customized cushion with the conventional one. Material and methods Each participant's face was replicated by using a 3-dimensional scanner and reverse-engineering technology, and computer numerical control techniques were used to design and manufacture customized cushions. Forty participants were randomly divided into 2 groups, a control group with conventional cushions and an experimental group with customized cushions. The saturation level of peripheral oxygen, apnea-hypopnea index, leakage data, and answers to a comfort questionnaire were examined. Results Customized and conventional cushions were compared with independent sampling t tests and relational analyses. A significant difference was found in the apnea-hypopnea index (P=.001) of participants with the customized cushion and those with the conventional cushion. Participants with the conventional cushion had a lower apnea-hypopnea index. The customized cushion applied less headgear force and fit better than the conventional cushion. The leakage volume, saturation of peripheral oxygen (SpO2), treatment compliance, and degree of comfort were not significantly different between the groups. Conclusions Customized nasal mask cushions fit better and reduce the force applied by the headgear. Participants using a customized cushion showed an improved apnea-hypopnea index.",
author = "Cheng, {Yih Lin} and Hsu, {Ding Yang} and Lee, {Hsin Chien} and Bien, {Mauo Ying}",
year = "2015",
month = "1",
day = "1",
doi = "10.1016/j.prosdent.2014.01.030",
language = "English",
volume = "113",
pages = "29--34.e1",
journal = "Journal of Prosthetic Dentistry",
issn = "0022-3913",
publisher = "Mosby Inc.",
number = "1",

}

TY - JOUR

T1 - Clinical verification of patients with obstructive sleep apnea provided with a customized cushion for continuous positive airway pressure

AU - Cheng, Yih Lin

AU - Hsu, Ding Yang

AU - Lee, Hsin Chien

AU - Bien, Mauo Ying

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Statement of problem Patients with obstructive sleep apnea may stop breathing momentarily during sleep because of a narrow upper respiratory tract. One of the main treatments for obstructive sleep apnea is continuous positive airway pressure. However, after long-term treatment, patients tend to complain about the leakage, inconvenience, and discomfort of the nasal mask. Purpose The purpose of the study was to develop customized cushions and compare the clinical performance of the customized cushion with the conventional one. Material and methods Each participant's face was replicated by using a 3-dimensional scanner and reverse-engineering technology, and computer numerical control techniques were used to design and manufacture customized cushions. Forty participants were randomly divided into 2 groups, a control group with conventional cushions and an experimental group with customized cushions. The saturation level of peripheral oxygen, apnea-hypopnea index, leakage data, and answers to a comfort questionnaire were examined. Results Customized and conventional cushions were compared with independent sampling t tests and relational analyses. A significant difference was found in the apnea-hypopnea index (P=.001) of participants with the customized cushion and those with the conventional cushion. Participants with the conventional cushion had a lower apnea-hypopnea index. The customized cushion applied less headgear force and fit better than the conventional cushion. The leakage volume, saturation of peripheral oxygen (SpO2), treatment compliance, and degree of comfort were not significantly different between the groups. Conclusions Customized nasal mask cushions fit better and reduce the force applied by the headgear. Participants using a customized cushion showed an improved apnea-hypopnea index.

AB - Statement of problem Patients with obstructive sleep apnea may stop breathing momentarily during sleep because of a narrow upper respiratory tract. One of the main treatments for obstructive sleep apnea is continuous positive airway pressure. However, after long-term treatment, patients tend to complain about the leakage, inconvenience, and discomfort of the nasal mask. Purpose The purpose of the study was to develop customized cushions and compare the clinical performance of the customized cushion with the conventional one. Material and methods Each participant's face was replicated by using a 3-dimensional scanner and reverse-engineering technology, and computer numerical control techniques were used to design and manufacture customized cushions. Forty participants were randomly divided into 2 groups, a control group with conventional cushions and an experimental group with customized cushions. The saturation level of peripheral oxygen, apnea-hypopnea index, leakage data, and answers to a comfort questionnaire were examined. Results Customized and conventional cushions were compared with independent sampling t tests and relational analyses. A significant difference was found in the apnea-hypopnea index (P=.001) of participants with the customized cushion and those with the conventional cushion. Participants with the conventional cushion had a lower apnea-hypopnea index. The customized cushion applied less headgear force and fit better than the conventional cushion. The leakage volume, saturation of peripheral oxygen (SpO2), treatment compliance, and degree of comfort were not significantly different between the groups. Conclusions Customized nasal mask cushions fit better and reduce the force applied by the headgear. Participants using a customized cushion showed an improved apnea-hypopnea index.

UR - http://www.scopus.com/inward/record.url?scp=84920540745&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920540745&partnerID=8YFLogxK

U2 - 10.1016/j.prosdent.2014.01.030

DO - 10.1016/j.prosdent.2014.01.030

M3 - Article

C2 - 25280988

AN - SCOPUS:84920540745

VL - 113

SP - 29-34.e1

JO - Journal of Prosthetic Dentistry

JF - Journal of Prosthetic Dentistry

SN - 0022-3913

IS - 1

ER -