Clinical, electrophysiological characteristics, and radiofrequency catheter ablation of atrial tachycardia near the apex of Koch's triangle

Ling Ping Lai, Jiunn Lee Lin, Ting Fu Chen, Wen Chin Ko, Wen Pin Lien

Research output: Contribution to journalArticle

51 Citations (Scopus)

Abstract

Atrial tachycardia, with its focus near the apex of Koch's triangle, may carry a potential risk of atrioventricular block during radiofrequency catheter ablation. The efficacy and safety of this procedure have never been addressed. The characteristics and catheter ablation results are reported for six patients with atrial tachycardia near the apex of Koch's triangle. All six patients were female aged 49.6 ± 9.3 years (range 39-63). Organic heart disease was present in 3 (50%) of the 6 patients. The P wave in surface ECG had a mean axis of - 28°(range - 90°- + 30°) in the frontal plane. The catheter ablation was guided by activation sequence mapping. The energy was titrated from low power level. Atrial overdrive pacing was used to monitor the atrioventricular conduction should accelerated junctional rhythm occur. At the final successful ablation site, the local atrial activation was 41.8 ± 9.1 ms before the P wave and His-bundle potential was present in 5 of the 6 patients. All patients had their atrial tachycardia eliminated without recurrence or heart black during a follow-up period of 17.7 ± 8.5 months (range 6-30). In conclusion, atrial tachycardia near the apex of Koch's triangle has distinct clinical and electrophysiological features. Radiofrequency catheter ablation can be performed effectively. However, extreme care must be taken to prevent inadvertent atrioventricular block. Titrated energy application and continuous monitoring of atrioventricular conduction are mandatory.

Original languageEnglish
Pages (from-to)367-374
Number of pages8
JournalPACE - Pacing and Clinical Electrophysiology
Volume21
Issue number2
DOIs
Publication statusPublished - Mar 10 1998
Externally publishedYes

Fingerprint

Catheter Ablation
Tachycardia
Atrioventricular Block
Bundle of His
Heart Diseases
Electrocardiography
Safety
Recurrence

Keywords

  • Atrial tachycardia
  • Catheter ablation
  • Koch's triangle

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Clinical, electrophysiological characteristics, and radiofrequency catheter ablation of atrial tachycardia near the apex of Koch's triangle. / Lai, Ling Ping; Lin, Jiunn Lee; Chen, Ting Fu; Ko, Wen Chin; Lien, Wen Pin.

In: PACE - Pacing and Clinical Electrophysiology, Vol. 21, No. 2, 10.03.1998, p. 367-374.

Research output: Contribution to journalArticle

@article{4bce6494629e41d28d9eda7a743065a7,
title = "Clinical, electrophysiological characteristics, and radiofrequency catheter ablation of atrial tachycardia near the apex of Koch's triangle",
abstract = "Atrial tachycardia, with its focus near the apex of Koch's triangle, may carry a potential risk of atrioventricular block during radiofrequency catheter ablation. The efficacy and safety of this procedure have never been addressed. The characteristics and catheter ablation results are reported for six patients with atrial tachycardia near the apex of Koch's triangle. All six patients were female aged 49.6 ± 9.3 years (range 39-63). Organic heart disease was present in 3 (50{\%}) of the 6 patients. The P wave in surface ECG had a mean axis of - 28°(range - 90°- + 30°) in the frontal plane. The catheter ablation was guided by activation sequence mapping. The energy was titrated from low power level. Atrial overdrive pacing was used to monitor the atrioventricular conduction should accelerated junctional rhythm occur. At the final successful ablation site, the local atrial activation was 41.8 ± 9.1 ms before the P wave and His-bundle potential was present in 5 of the 6 patients. All patients had their atrial tachycardia eliminated without recurrence or heart black during a follow-up period of 17.7 ± 8.5 months (range 6-30). In conclusion, atrial tachycardia near the apex of Koch's triangle has distinct clinical and electrophysiological features. Radiofrequency catheter ablation can be performed effectively. However, extreme care must be taken to prevent inadvertent atrioventricular block. Titrated energy application and continuous monitoring of atrioventricular conduction are mandatory.",
keywords = "Atrial tachycardia, Catheter ablation, Koch's triangle",
author = "Lai, {Ling Ping} and Lin, {Jiunn Lee} and Chen, {Ting Fu} and Ko, {Wen Chin} and Lien, {Wen Pin}",
year = "1998",
month = "3",
day = "10",
doi = "10.1111/j.1540-8159.1998.tb00060.x",
language = "English",
volume = "21",
pages = "367--374",
journal = "PACE - Pacing and Clinical Electrophysiology",
issn = "0147-8389",
publisher = "Wiley-Blackwell",
number = "2",

}

TY - JOUR

T1 - Clinical, electrophysiological characteristics, and radiofrequency catheter ablation of atrial tachycardia near the apex of Koch's triangle

AU - Lai, Ling Ping

AU - Lin, Jiunn Lee

AU - Chen, Ting Fu

AU - Ko, Wen Chin

AU - Lien, Wen Pin

PY - 1998/3/10

Y1 - 1998/3/10

N2 - Atrial tachycardia, with its focus near the apex of Koch's triangle, may carry a potential risk of atrioventricular block during radiofrequency catheter ablation. The efficacy and safety of this procedure have never been addressed. The characteristics and catheter ablation results are reported for six patients with atrial tachycardia near the apex of Koch's triangle. All six patients were female aged 49.6 ± 9.3 years (range 39-63). Organic heart disease was present in 3 (50%) of the 6 patients. The P wave in surface ECG had a mean axis of - 28°(range - 90°- + 30°) in the frontal plane. The catheter ablation was guided by activation sequence mapping. The energy was titrated from low power level. Atrial overdrive pacing was used to monitor the atrioventricular conduction should accelerated junctional rhythm occur. At the final successful ablation site, the local atrial activation was 41.8 ± 9.1 ms before the P wave and His-bundle potential was present in 5 of the 6 patients. All patients had their atrial tachycardia eliminated without recurrence or heart black during a follow-up period of 17.7 ± 8.5 months (range 6-30). In conclusion, atrial tachycardia near the apex of Koch's triangle has distinct clinical and electrophysiological features. Radiofrequency catheter ablation can be performed effectively. However, extreme care must be taken to prevent inadvertent atrioventricular block. Titrated energy application and continuous monitoring of atrioventricular conduction are mandatory.

AB - Atrial tachycardia, with its focus near the apex of Koch's triangle, may carry a potential risk of atrioventricular block during radiofrequency catheter ablation. The efficacy and safety of this procedure have never been addressed. The characteristics and catheter ablation results are reported for six patients with atrial tachycardia near the apex of Koch's triangle. All six patients were female aged 49.6 ± 9.3 years (range 39-63). Organic heart disease was present in 3 (50%) of the 6 patients. The P wave in surface ECG had a mean axis of - 28°(range - 90°- + 30°) in the frontal plane. The catheter ablation was guided by activation sequence mapping. The energy was titrated from low power level. Atrial overdrive pacing was used to monitor the atrioventricular conduction should accelerated junctional rhythm occur. At the final successful ablation site, the local atrial activation was 41.8 ± 9.1 ms before the P wave and His-bundle potential was present in 5 of the 6 patients. All patients had their atrial tachycardia eliminated without recurrence or heart black during a follow-up period of 17.7 ± 8.5 months (range 6-30). In conclusion, atrial tachycardia near the apex of Koch's triangle has distinct clinical and electrophysiological features. Radiofrequency catheter ablation can be performed effectively. However, extreme care must be taken to prevent inadvertent atrioventricular block. Titrated energy application and continuous monitoring of atrioventricular conduction are mandatory.

KW - Atrial tachycardia

KW - Catheter ablation

KW - Koch's triangle

UR - http://www.scopus.com/inward/record.url?scp=0031913937&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031913937&partnerID=8YFLogxK

U2 - 10.1111/j.1540-8159.1998.tb00060.x

DO - 10.1111/j.1540-8159.1998.tb00060.x

M3 - Article

VL - 21

SP - 367

EP - 374

JO - PACE - Pacing and Clinical Electrophysiology

JF - PACE - Pacing and Clinical Electrophysiology

SN - 0147-8389

IS - 2

ER -