Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion - dynamic sonographic evaluation

Research output: Contribution to journalArticle

47 Citations (Scopus)

Abstract

Background: Clavicular hook plates are effective fixation devices for distal clavicle fractures and severe acromioclavicular joint dislocations. However, increasing number of studies has revealed that subacromial portion of the hook may induce acromial bony erosion, shoulder impingement, or even rotator cuff damage. By sonographic evaluation, we thus intended to determine whether the presence of hook plate may induce subacromial shoulder impingement and its relationship relative to surrounding subacromial structures.Methods: We prospectively followed 40 patients with either distal clavicle fracture or acromioclavicular joint dislocation that had surgery using the Arbeitsgemeinschaft für Osteosynthesefragen (AO) clavicular hook plate. All patients were evaluated by monthly clinical and radiographic examinations. Static and dynamic musculoskeletal sonography examinations were performed at final follow-up before implant removal. Clinical results for pain, shoulder function, and range of motion were evaluated using Constant-Murley and Disability of Arm, Shoulder, and Hand (DASH) scores.Results: Clinically, 15 out of 40 patients (37.5%) presented with subacromial impingement syndrome and their functional scores were poorer than the non-impinged patients. Among them, six patients were noted to have rotator cuff lesion. Acromial erosion caused by hook pressure developed in 20 patients (50%).Conclusions: We demonstrated by musculoskeletal sonography that clavicular hook plate caused subacromial shoulder impingement and rotator cuff lesion. The data also suggest an association between hardware-induced impingement and poorer functional scores. To our knowledge, the only solution is removal of the implant after bony consolidation/ligamentous healing has taken place. Thus, we advocate the removal of the implant as soon as bony union and/or ligamentous healing is achieved.

Original languageEnglish
Article number6
JournalJournal of Orthopaedic Surgery and Research
Volume9
Issue number1
DOIs
Publication statusPublished - Feb 6 2014

Fingerprint

Shoulder Impingement Syndrome
Acromioclavicular Joint
Clavicle
Rotator Cuff
Joint Dislocations
Ultrasonography
Shoulder Pain
Articular Range of Motion
Arm
Hand
Pressure
Equipment and Supplies

Keywords

  • Hook plate
  • Rotator cuff
  • Subacromial impingement

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

@article{1decce8cde4e48a9a9444e02d22c8474,
title = "Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion - dynamic sonographic evaluation",
abstract = "Background: Clavicular hook plates are effective fixation devices for distal clavicle fractures and severe acromioclavicular joint dislocations. However, increasing number of studies has revealed that subacromial portion of the hook may induce acromial bony erosion, shoulder impingement, or even rotator cuff damage. By sonographic evaluation, we thus intended to determine whether the presence of hook plate may induce subacromial shoulder impingement and its relationship relative to surrounding subacromial structures.Methods: We prospectively followed 40 patients with either distal clavicle fracture or acromioclavicular joint dislocation that had surgery using the Arbeitsgemeinschaft f{\"u}r Osteosynthesefragen (AO) clavicular hook plate. All patients were evaluated by monthly clinical and radiographic examinations. Static and dynamic musculoskeletal sonography examinations were performed at final follow-up before implant removal. Clinical results for pain, shoulder function, and range of motion were evaluated using Constant-Murley and Disability of Arm, Shoulder, and Hand (DASH) scores.Results: Clinically, 15 out of 40 patients (37.5{\%}) presented with subacromial impingement syndrome and their functional scores were poorer than the non-impinged patients. Among them, six patients were noted to have rotator cuff lesion. Acromial erosion caused by hook pressure developed in 20 patients (50{\%}).Conclusions: We demonstrated by musculoskeletal sonography that clavicular hook plate caused subacromial shoulder impingement and rotator cuff lesion. The data also suggest an association between hardware-induced impingement and poorer functional scores. To our knowledge, the only solution is removal of the implant after bony consolidation/ligamentous healing has taken place. Thus, we advocate the removal of the implant as soon as bony union and/or ligamentous healing is achieved.",
keywords = "Hook plate, Rotator cuff, Subacromial impingement",
author = "Lin, {Hsin Yu} and Wong, {Poo Kuang} and Ho, {Wei Pin} and Chuang, {Tai Yuan} and Liao, {Yi Shyan} and Wong, {Chin Chean}",
year = "2014",
month = "2",
day = "6",
doi = "10.1186/1749-799X-9-6",
language = "English",
volume = "9",
journal = "Journal of Orthopaedic Surgery and Research",
issn = "1749-799X",
publisher = "BioMed Central",
number = "1",

}

TY - JOUR

T1 - Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion - dynamic sonographic evaluation

AU - Lin, Hsin Yu

AU - Wong, Poo Kuang

AU - Ho, Wei Pin

AU - Chuang, Tai Yuan

AU - Liao, Yi Shyan

AU - Wong, Chin Chean

PY - 2014/2/6

Y1 - 2014/2/6

N2 - Background: Clavicular hook plates are effective fixation devices for distal clavicle fractures and severe acromioclavicular joint dislocations. However, increasing number of studies has revealed that subacromial portion of the hook may induce acromial bony erosion, shoulder impingement, or even rotator cuff damage. By sonographic evaluation, we thus intended to determine whether the presence of hook plate may induce subacromial shoulder impingement and its relationship relative to surrounding subacromial structures.Methods: We prospectively followed 40 patients with either distal clavicle fracture or acromioclavicular joint dislocation that had surgery using the Arbeitsgemeinschaft für Osteosynthesefragen (AO) clavicular hook plate. All patients were evaluated by monthly clinical and radiographic examinations. Static and dynamic musculoskeletal sonography examinations were performed at final follow-up before implant removal. Clinical results for pain, shoulder function, and range of motion were evaluated using Constant-Murley and Disability of Arm, Shoulder, and Hand (DASH) scores.Results: Clinically, 15 out of 40 patients (37.5%) presented with subacromial impingement syndrome and their functional scores were poorer than the non-impinged patients. Among them, six patients were noted to have rotator cuff lesion. Acromial erosion caused by hook pressure developed in 20 patients (50%).Conclusions: We demonstrated by musculoskeletal sonography that clavicular hook plate caused subacromial shoulder impingement and rotator cuff lesion. The data also suggest an association between hardware-induced impingement and poorer functional scores. To our knowledge, the only solution is removal of the implant after bony consolidation/ligamentous healing has taken place. Thus, we advocate the removal of the implant as soon as bony union and/or ligamentous healing is achieved.

AB - Background: Clavicular hook plates are effective fixation devices for distal clavicle fractures and severe acromioclavicular joint dislocations. However, increasing number of studies has revealed that subacromial portion of the hook may induce acromial bony erosion, shoulder impingement, or even rotator cuff damage. By sonographic evaluation, we thus intended to determine whether the presence of hook plate may induce subacromial shoulder impingement and its relationship relative to surrounding subacromial structures.Methods: We prospectively followed 40 patients with either distal clavicle fracture or acromioclavicular joint dislocation that had surgery using the Arbeitsgemeinschaft für Osteosynthesefragen (AO) clavicular hook plate. All patients were evaluated by monthly clinical and radiographic examinations. Static and dynamic musculoskeletal sonography examinations were performed at final follow-up before implant removal. Clinical results for pain, shoulder function, and range of motion were evaluated using Constant-Murley and Disability of Arm, Shoulder, and Hand (DASH) scores.Results: Clinically, 15 out of 40 patients (37.5%) presented with subacromial impingement syndrome and their functional scores were poorer than the non-impinged patients. Among them, six patients were noted to have rotator cuff lesion. Acromial erosion caused by hook pressure developed in 20 patients (50%).Conclusions: We demonstrated by musculoskeletal sonography that clavicular hook plate caused subacromial shoulder impingement and rotator cuff lesion. The data also suggest an association between hardware-induced impingement and poorer functional scores. To our knowledge, the only solution is removal of the implant after bony consolidation/ligamentous healing has taken place. Thus, we advocate the removal of the implant as soon as bony union and/or ligamentous healing is achieved.

KW - Hook plate

KW - Rotator cuff

KW - Subacromial impingement

UR - http://www.scopus.com/inward/record.url?scp=84893865886&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893865886&partnerID=8YFLogxK

U2 - 10.1186/1749-799X-9-6

DO - 10.1186/1749-799X-9-6

M3 - Article

C2 - 24502688

AN - SCOPUS:84893865886

VL - 9

JO - Journal of Orthopaedic Surgery and Research

JF - Journal of Orthopaedic Surgery and Research

SN - 1749-799X

IS - 1

M1 - 6

ER -