Abstract

Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3% at tube potentials from 40 Vp to 125 kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures.

Original languageEnglish
Pages (from-to)883-891
Number of pages9
JournalApplied Radiation and Isotopes
Volume57
Issue number6
DOIs
Publication statusPublished - Dec 1 2002
Externally publishedYes

Fingerprint

radiology
thermoluminescence
metal oxide semiconductors
dosimeters
field effect transistors
sensitivity
linearity
dosage
entrances
projection
tubes
skull
spine
chest
radiation dosage
energy

Keywords

  • Diagnostic radiology
  • MOSFET dosimeter
  • Radiation detection
  • TLD dosimeter

ASJC Scopus subject areas

  • Radiation

Cite this

Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF : Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology. / Dong, S. L.; Chu, T. C.; Lan, G. Y.; Wu, T. H.; Lin, Y. C.; Lee, J. S.

In: Applied Radiation and Isotopes, Vol. 57, No. 6, 01.12.2002, p. 883-891.

Research output: Contribution to journalArticle

@article{4046c62df65348278dbe4d79723b11cc,
title = "Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF: Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology",
abstract = "Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3{\%} at tube potentials from 40 Vp to 125 kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures.",
keywords = "Diagnostic radiology, MOSFET dosimeter, Radiation detection, TLD dosimeter, Diagnostic radiology, MOSFET dosimeter, Radiation detection, TLD dosimeter",
author = "Dong, {S. L.} and Chu, {T. C.} and Lan, {G. Y.} and Wu, {T. H.} and Lin, {Y. C.} and Lee, {J. S.}",
year = "2002",
month = "12",
day = "1",
doi = "10.1016/S0969-8043(02)00235-X",
language = "English",
volume = "57",
pages = "883--891",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Elsevier Limited",
number = "6",

}

TY - JOUR

T1 - Characterization of high-sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF

T2 - Mg,Cu,P thermoluminescence dosimeters for use in diagnostic radiology

AU - Dong, S. L.

AU - Chu, T. C.

AU - Lan, G. Y.

AU - Wu, T. H.

AU - Lin, Y. C.

AU - Lee, J. S.

PY - 2002/12/1

Y1 - 2002/12/1

N2 - Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3% at tube potentials from 40 Vp to 125 kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures.

AB - Monitoring radiation exposure during diagnostic radiographic procedures has recently become an area of interest. In recent years, the LiF:Mg,Cu,P thermoluminescence dosimeter (TLD-100H) and the highly sensitive metal oxide semiconductor field effect transistor (MOSFET) dosimeter were introduced as good candidates for entrance skin dose measurements in diagnostic radiology. In the present study, the TLD-100H and the MOSFET dosimeters were evaluated for sensitivity, linearity, energy, angular dependence, and post-exposure response. Our results indicate that the TLD-100H dosimeter has excellent linearity within diagnostic energy ranges and its sensitivity variations were under 3% at tube potentials from 40 Vp to 125 kVp. Good linearity was also observed with the MOSFET dosimeter, but in low-dose regions the values are less reliable and were found to be a function of the tube potentials. Both dosimeters also presented predictable angular dependence in this study. Our findings suggest that the TLD-100H dosimeter is more appropriate for low-dose diagnostic procedures such as chest and skull projections. The MOSFET dosimeter system is valuable for entrance skin dose measurement with lumbar spine projections and certain fluoroscopic procedures.

KW - Diagnostic radiology

KW - MOSFET dosimeter

KW - Radiation detection

KW - TLD dosimeter

KW - Diagnostic radiology

KW - MOSFET dosimeter

KW - Radiation detection

KW - TLD dosimeter

UR - http://www.scopus.com/inward/record.url?scp=0036888598&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036888598&partnerID=8YFLogxK

U2 - 10.1016/S0969-8043(02)00235-X

DO - 10.1016/S0969-8043(02)00235-X

M3 - Article

C2 - 12406633

AN - SCOPUS:0036888598

VL - 57

SP - 883

EP - 891

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

IS - 6

ER -