Body Positions in the Diagnosis of Right-to-Left Shunt by Contrast Transcranial Doppler

Ke Han, Yingqi Xing, Yi Yang, A. Ching Chao, Wen Yung Sheng, Han Hwa Hu, Jiang Wu

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Contrast transcranial Doppler (c-TCD) is sensitive in detecting right-to-left shunt (RLS). However, the methodology and ideal posture are controversial. Consecutive migraine patients were prospectively examined for RLS using c-TCD. Each patient was examined while at rest and subsequently with the Valsalva maneuver (VM) in three positions: supine, left lateral decubitus and right lateral decubitus. RLS was diagnosed with at least one microbubble detected at any position. RLS was highest in the left lateral decubitus position, both during rest and with VM. The left lateral decubitus position was associated with the highest total number of microbubbles and greater shunt grades. Patients who tested positive in the other two positions had the lowest index position failure rate during rest in the left lateral decubitus position. In some patients in whom RLS is detected at rest, it may not be detected (false negative) under VM. To ensure c-TCD's the sensitivity to RLS, testing in the left lateral decubitus position at rest and under VM is suggested; testing in other positions is necessary to avoid false negatives.

Original languageEnglish
Pages (from-to)2376-2381
Number of pages6
JournalUltrasound in Medicine and Biology
Volume41
Issue number9
DOIs
Publication statusPublished - Sep 1 2015

Fingerprint

Valsalva Maneuver
shunts
Valsalva exercise
Microbubbles
Supine Position
Migraine Disorders
Posture
supine position
posture
grade
methodology
sensitivity

Keywords

  • Contrast transcranial Doppler
  • Patent foramen ovale
  • Position
  • Right-to-left shunt

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Biophysics
  • Acoustics and Ultrasonics

Cite this

Body Positions in the Diagnosis of Right-to-Left Shunt by Contrast Transcranial Doppler. / Han, Ke; Xing, Yingqi; Yang, Yi; Chao, A. Ching; Sheng, Wen Yung; Hu, Han Hwa; Wu, Jiang.

In: Ultrasound in Medicine and Biology, Vol. 41, No. 9, 01.09.2015, p. 2376-2381.

Research output: Contribution to journalArticle

Han, Ke ; Xing, Yingqi ; Yang, Yi ; Chao, A. Ching ; Sheng, Wen Yung ; Hu, Han Hwa ; Wu, Jiang. / Body Positions in the Diagnosis of Right-to-Left Shunt by Contrast Transcranial Doppler. In: Ultrasound in Medicine and Biology. 2015 ; Vol. 41, No. 9. pp. 2376-2381.
@article{092d2be2ddef42478087669e492c7743,
title = "Body Positions in the Diagnosis of Right-to-Left Shunt by Contrast Transcranial Doppler",
abstract = "Contrast transcranial Doppler (c-TCD) is sensitive in detecting right-to-left shunt (RLS). However, the methodology and ideal posture are controversial. Consecutive migraine patients were prospectively examined for RLS using c-TCD. Each patient was examined while at rest and subsequently with the Valsalva maneuver (VM) in three positions: supine, left lateral decubitus and right lateral decubitus. RLS was diagnosed with at least one microbubble detected at any position. RLS was highest in the left lateral decubitus position, both during rest and with VM. The left lateral decubitus position was associated with the highest total number of microbubbles and greater shunt grades. Patients who tested positive in the other two positions had the lowest index position failure rate during rest in the left lateral decubitus position. In some patients in whom RLS is detected at rest, it may not be detected (false negative) under VM. To ensure c-TCD's the sensitivity to RLS, testing in the left lateral decubitus position at rest and under VM is suggested; testing in other positions is necessary to avoid false negatives.",
keywords = "Contrast transcranial Doppler, Patent foramen ovale, Position, Right-to-left shunt",
author = "Ke Han and Yingqi Xing and Yi Yang and Chao, {A. Ching} and Sheng, {Wen Yung} and Hu, {Han Hwa} and Jiang Wu",
year = "2015",
month = "9",
day = "1",
doi = "10.1016/j.ultrasmedbio.2015.04.023",
language = "English",
volume = "41",
pages = "2376--2381",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier USA",
number = "9",

}

TY - JOUR

T1 - Body Positions in the Diagnosis of Right-to-Left Shunt by Contrast Transcranial Doppler

AU - Han, Ke

AU - Xing, Yingqi

AU - Yang, Yi

AU - Chao, A. Ching

AU - Sheng, Wen Yung

AU - Hu, Han Hwa

AU - Wu, Jiang

PY - 2015/9/1

Y1 - 2015/9/1

N2 - Contrast transcranial Doppler (c-TCD) is sensitive in detecting right-to-left shunt (RLS). However, the methodology and ideal posture are controversial. Consecutive migraine patients were prospectively examined for RLS using c-TCD. Each patient was examined while at rest and subsequently with the Valsalva maneuver (VM) in three positions: supine, left lateral decubitus and right lateral decubitus. RLS was diagnosed with at least one microbubble detected at any position. RLS was highest in the left lateral decubitus position, both during rest and with VM. The left lateral decubitus position was associated with the highest total number of microbubbles and greater shunt grades. Patients who tested positive in the other two positions had the lowest index position failure rate during rest in the left lateral decubitus position. In some patients in whom RLS is detected at rest, it may not be detected (false negative) under VM. To ensure c-TCD's the sensitivity to RLS, testing in the left lateral decubitus position at rest and under VM is suggested; testing in other positions is necessary to avoid false negatives.

AB - Contrast transcranial Doppler (c-TCD) is sensitive in detecting right-to-left shunt (RLS). However, the methodology and ideal posture are controversial. Consecutive migraine patients were prospectively examined for RLS using c-TCD. Each patient was examined while at rest and subsequently with the Valsalva maneuver (VM) in three positions: supine, left lateral decubitus and right lateral decubitus. RLS was diagnosed with at least one microbubble detected at any position. RLS was highest in the left lateral decubitus position, both during rest and with VM. The left lateral decubitus position was associated with the highest total number of microbubbles and greater shunt grades. Patients who tested positive in the other two positions had the lowest index position failure rate during rest in the left lateral decubitus position. In some patients in whom RLS is detected at rest, it may not be detected (false negative) under VM. To ensure c-TCD's the sensitivity to RLS, testing in the left lateral decubitus position at rest and under VM is suggested; testing in other positions is necessary to avoid false negatives.

KW - Contrast transcranial Doppler

KW - Patent foramen ovale

KW - Position

KW - Right-to-left shunt

UR - http://www.scopus.com/inward/record.url?scp=84938216469&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84938216469&partnerID=8YFLogxK

U2 - 10.1016/j.ultrasmedbio.2015.04.023

DO - 10.1016/j.ultrasmedbio.2015.04.023

M3 - Article

C2 - 26067785

AN - SCOPUS:84938216469

VL - 41

SP - 2376

EP - 2381

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 9

ER -