Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws

Shan Wei Yang, Shyh Ming Kuo, Shwu Jen Chang, Tian Shiang Su, Hsiang H O Chen, Jenn Huei Renn, Ting Sheng Lin

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking plate and divided into 2 groups based on whether the proximal metaphyseal screw holes of the plate were inserted with either cannulated locking screws or noncannulated cortical locking screws. An axial compressive load was applied to cause failure in each specimen using a materials testing instrument. The axial stiffness and maximum failure strength in axial loading were recorded. Axial stiffness of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.006). Axial failure strength of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.002). The failure mode observed in all specimens was a permanent screw-bending deformity over the head-shaft junction of proximal metaphyseal screws, irrespective of whether they were cannulated or noncannulated cortical locking screws. Fixation with noncannulated cortical locking screws offered more stability than cannulated locking screws with regard to axial stiffness and failure strength in a porcine model with unstable proximal tibial fractures.

Original languageEnglish
JournalOrthopedics
Volume36
Issue number10
DOIs
Publication statusPublished - Oct 2013

Fingerprint

Tibial Fractures
Swine
Materials Testing
Weight-Bearing
Tibia
Head

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws. / Yang, Shan Wei; Kuo, Shyh Ming; Chang, Shwu Jen; Su, Tian Shiang; Chen, Hsiang H O; Renn, Jenn Huei; Lin, Ting Sheng.

In: Orthopedics, Vol. 36, No. 10, 10.2013.

Research output: Contribution to journalArticle

Yang, Shan Wei ; Kuo, Shyh Ming ; Chang, Shwu Jen ; Su, Tian Shiang ; Chen, Hsiang H O ; Renn, Jenn Huei ; Lin, Ting Sheng. / Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws. In: Orthopedics. 2013 ; Vol. 36, No. 10.
@article{afa19b120fdb45c5b61e45f93539a3e9,
title = "Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws",
abstract = "The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking plate and divided into 2 groups based on whether the proximal metaphyseal screw holes of the plate were inserted with either cannulated locking screws or noncannulated cortical locking screws. An axial compressive load was applied to cause failure in each specimen using a materials testing instrument. The axial stiffness and maximum failure strength in axial loading were recorded. Axial stiffness of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.006). Axial failure strength of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.002). The failure mode observed in all specimens was a permanent screw-bending deformity over the head-shaft junction of proximal metaphyseal screws, irrespective of whether they were cannulated or noncannulated cortical locking screws. Fixation with noncannulated cortical locking screws offered more stability than cannulated locking screws with regard to axial stiffness and failure strength in a porcine model with unstable proximal tibial fractures.",
author = "Yang, {Shan Wei} and Kuo, {Shyh Ming} and Chang, {Shwu Jen} and Su, {Tian Shiang} and Chen, {Hsiang H O} and Renn, {Jenn Huei} and Lin, {Ting Sheng}",
year = "2013",
month = "10",
doi = "10.3928/01477447-20130920-26",
language = "English",
volume = "36",
journal = "Orthopedics",
issn = "0147-7447",
publisher = "Slack Incorporated",
number = "10",

}

TY - JOUR

T1 - Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws

AU - Yang, Shan Wei

AU - Kuo, Shyh Ming

AU - Chang, Shwu Jen

AU - Su, Tian Shiang

AU - Chen, Hsiang H O

AU - Renn, Jenn Huei

AU - Lin, Ting Sheng

PY - 2013/10

Y1 - 2013/10

N2 - The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking plate and divided into 2 groups based on whether the proximal metaphyseal screw holes of the plate were inserted with either cannulated locking screws or noncannulated cortical locking screws. An axial compressive load was applied to cause failure in each specimen using a materials testing instrument. The axial stiffness and maximum failure strength in axial loading were recorded. Axial stiffness of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.006). Axial failure strength of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.002). The failure mode observed in all specimens was a permanent screw-bending deformity over the head-shaft junction of proximal metaphyseal screws, irrespective of whether they were cannulated or noncannulated cortical locking screws. Fixation with noncannulated cortical locking screws offered more stability than cannulated locking screws with regard to axial stiffness and failure strength in a porcine model with unstable proximal tibial fractures.

AB - The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking plate and divided into 2 groups based on whether the proximal metaphyseal screw holes of the plate were inserted with either cannulated locking screws or noncannulated cortical locking screws. An axial compressive load was applied to cause failure in each specimen using a materials testing instrument. The axial stiffness and maximum failure strength in axial loading were recorded. Axial stiffness of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.006). Axial failure strength of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P5.002). The failure mode observed in all specimens was a permanent screw-bending deformity over the head-shaft junction of proximal metaphyseal screws, irrespective of whether they were cannulated or noncannulated cortical locking screws. Fixation with noncannulated cortical locking screws offered more stability than cannulated locking screws with regard to axial stiffness and failure strength in a porcine model with unstable proximal tibial fractures.

UR - http://www.scopus.com/inward/record.url?scp=84885756098&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885756098&partnerID=8YFLogxK

U2 - 10.3928/01477447-20130920-26

DO - 10.3928/01477447-20130920-26

M3 - Article

C2 - 24093710

AN - SCOPUS:84885756098

VL - 36

JO - Orthopedics

JF - Orthopedics

SN - 0147-7447

IS - 10

ER -