Assessment of elevation of and rapid change in left ventricular filling pressure using a novel global strain imaging diastolic index

Shuo Ju Chiang, Masao Daimon, Katsuhisa Ishii, Takayuki Kawata, Sakiko Miyazaki, Kuniaki Hirose, Ryoko Ichikawa, Katsumi Miyauch, Mei Hsiu Yeh, Nen Chung Chang, Hiroyuki Daida

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Background: The aim of this study was to determine whether global strain imaging diastolic index (SIDI) obtained using 2-D speckle tracking imaging (2DSI) could predict elevation in and rapid change of LV filling pressure. Methods and Results: Patients (n=126) underwent echocardiography and 2DSI during simultaneous cardiac catheterization. There were 60 patients in whom the same measurements were repeated 5 min after i.v. glyceryl trinitrate. LV pre-atrial contraction pressure (pre-A) was measured as a surrogate of LV filling pressure. SIDI was defined as the change of LV longitudinal strain measured using 2DSI during the first one-third of diastole. Then, longitudinal global SIDI (L-global SIDI) was calculated as the mean SIDI of 18 LV segments. Mitral inflow and tissue Doppler imaging were also assessed. Among 126 patients, 93 patients had LV pre-A ≥15 mmHg. L-global SIDI had a better correlation with LV pre-A (P

Original languageEnglish
Pages (from-to)419-427
Number of pages9
JournalCirculation Journal
Volume78
Issue number2
DOIs
Publication statusPublished - 2014

Fingerprint

Ventricular Pressure
Pressure
Atrial Pressure
Diastole
Nitroglycerin
Cardiac Catheterization
Echocardiography

Keywords

  • Diastole
  • Echocardiography
  • Hemodynamics
  • Speckle myocardial imaging

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Medicine(all)

Cite this

Assessment of elevation of and rapid change in left ventricular filling pressure using a novel global strain imaging diastolic index. / Chiang, Shuo Ju; Daimon, Masao; Ishii, Katsuhisa; Kawata, Takayuki; Miyazaki, Sakiko; Hirose, Kuniaki; Ichikawa, Ryoko; Miyauch, Katsumi; Yeh, Mei Hsiu; Chang, Nen Chung; Daida, Hiroyuki.

In: Circulation Journal, Vol. 78, No. 2, 2014, p. 419-427.

Research output: Contribution to journalArticle

Chiang, SJ, Daimon, M, Ishii, K, Kawata, T, Miyazaki, S, Hirose, K, Ichikawa, R, Miyauch, K, Yeh, MH, Chang, NC & Daida, H 2014, 'Assessment of elevation of and rapid change in left ventricular filling pressure using a novel global strain imaging diastolic index', Circulation Journal, vol. 78, no. 2, pp. 419-427. https://doi.org/10.1253/circj.CJ-13-0513
Chiang, Shuo Ju ; Daimon, Masao ; Ishii, Katsuhisa ; Kawata, Takayuki ; Miyazaki, Sakiko ; Hirose, Kuniaki ; Ichikawa, Ryoko ; Miyauch, Katsumi ; Yeh, Mei Hsiu ; Chang, Nen Chung ; Daida, Hiroyuki. / Assessment of elevation of and rapid change in left ventricular filling pressure using a novel global strain imaging diastolic index. In: Circulation Journal. 2014 ; Vol. 78, No. 2. pp. 419-427.
@article{6e1d96cf6eb94fe68445f4f740efc6e9,
title = "Assessment of elevation of and rapid change in left ventricular filling pressure using a novel global strain imaging diastolic index",
abstract = "Background: The aim of this study was to determine whether global strain imaging diastolic index (SIDI) obtained using 2-D speckle tracking imaging (2DSI) could predict elevation in and rapid change of LV filling pressure. Methods and Results: Patients (n=126) underwent echocardiography and 2DSI during simultaneous cardiac catheterization. There were 60 patients in whom the same measurements were repeated 5 min after i.v. glyceryl trinitrate. LV pre-atrial contraction pressure (pre-A) was measured as a surrogate of LV filling pressure. SIDI was defined as the change of LV longitudinal strain measured using 2DSI during the first one-third of diastole. Then, longitudinal global SIDI (L-global SIDI) was calculated as the mean SIDI of 18 LV segments. Mitral inflow and tissue Doppler imaging were also assessed. Among 126 patients, 93 patients had LV pre-A ≥15 mmHg. L-global SIDI had a better correlation with LV pre-A (P",
keywords = "Diastole, Echocardiography, Hemodynamics, Speckle myocardial imaging",
author = "Chiang, {Shuo Ju} and Masao Daimon and Katsuhisa Ishii and Takayuki Kawata and Sakiko Miyazaki and Kuniaki Hirose and Ryoko Ichikawa and Katsumi Miyauch and Yeh, {Mei Hsiu} and Chang, {Nen Chung} and Hiroyuki Daida",
year = "2014",
doi = "10.1253/circj.CJ-13-0513",
language = "English",
volume = "78",
pages = "419--427",
journal = "Circulation Journal",
issn = "1346-9843",
publisher = "Japanese Circulation Society",
number = "2",

}

TY - JOUR

T1 - Assessment of elevation of and rapid change in left ventricular filling pressure using a novel global strain imaging diastolic index

AU - Chiang, Shuo Ju

AU - Daimon, Masao

AU - Ishii, Katsuhisa

AU - Kawata, Takayuki

AU - Miyazaki, Sakiko

AU - Hirose, Kuniaki

AU - Ichikawa, Ryoko

AU - Miyauch, Katsumi

AU - Yeh, Mei Hsiu

AU - Chang, Nen Chung

AU - Daida, Hiroyuki

PY - 2014

Y1 - 2014

N2 - Background: The aim of this study was to determine whether global strain imaging diastolic index (SIDI) obtained using 2-D speckle tracking imaging (2DSI) could predict elevation in and rapid change of LV filling pressure. Methods and Results: Patients (n=126) underwent echocardiography and 2DSI during simultaneous cardiac catheterization. There were 60 patients in whom the same measurements were repeated 5 min after i.v. glyceryl trinitrate. LV pre-atrial contraction pressure (pre-A) was measured as a surrogate of LV filling pressure. SIDI was defined as the change of LV longitudinal strain measured using 2DSI during the first one-third of diastole. Then, longitudinal global SIDI (L-global SIDI) was calculated as the mean SIDI of 18 LV segments. Mitral inflow and tissue Doppler imaging were also assessed. Among 126 patients, 93 patients had LV pre-A ≥15 mmHg. L-global SIDI had a better correlation with LV pre-A (P

AB - Background: The aim of this study was to determine whether global strain imaging diastolic index (SIDI) obtained using 2-D speckle tracking imaging (2DSI) could predict elevation in and rapid change of LV filling pressure. Methods and Results: Patients (n=126) underwent echocardiography and 2DSI during simultaneous cardiac catheterization. There were 60 patients in whom the same measurements were repeated 5 min after i.v. glyceryl trinitrate. LV pre-atrial contraction pressure (pre-A) was measured as a surrogate of LV filling pressure. SIDI was defined as the change of LV longitudinal strain measured using 2DSI during the first one-third of diastole. Then, longitudinal global SIDI (L-global SIDI) was calculated as the mean SIDI of 18 LV segments. Mitral inflow and tissue Doppler imaging were also assessed. Among 126 patients, 93 patients had LV pre-A ≥15 mmHg. L-global SIDI had a better correlation with LV pre-A (P

KW - Diastole

KW - Echocardiography

KW - Hemodynamics

KW - Speckle myocardial imaging

UR - http://www.scopus.com/inward/record.url?scp=84892968260&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84892968260&partnerID=8YFLogxK

U2 - 10.1253/circj.CJ-13-0513

DO - 10.1253/circj.CJ-13-0513

M3 - Article

VL - 78

SP - 419

EP - 427

JO - Circulation Journal

JF - Circulation Journal

SN - 1346-9843

IS - 2

ER -