Abstract
Background: The aim of this study was to determine whether global strain imaging diastolic index (SIDI) obtained using 2-D speckle tracking imaging (2DSI) could predict elevation in and rapid change of LV filling pressure. Methods and Results: Patients (n=126) underwent echocardiography and 2DSI during simultaneous cardiac catheterization. There were 60 patients in whom the same measurements were repeated 5 min after i.v. glyceryl trinitrate. LV pre-atrial contraction pressure (pre-A) was measured as a surrogate of LV filling pressure. SIDI was defined as the change of LV longitudinal strain measured using 2DSI during the first one-third of diastole. Then, longitudinal global SIDI (L-global SIDI) was calculated as the mean SIDI of 18 LV segments. Mitral inflow and tissue Doppler imaging were also assessed. Among 126 patients, 93 patients had LV pre-A ≥15 mmHg. L-global SIDI had a better correlation with LV pre-A (P
Original language | English |
---|---|
Pages (from-to) | 419-427 |
Number of pages | 9 |
Journal | Circulation Journal |
Volume | 78 |
Issue number | 2 |
DOIs | |
Publication status | Published - 2014 |
Keywords
- Diastole
- Echocardiography
- Hemodynamics
- Speckle myocardial imaging
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
- Medicine(all)