Are trueFISP images T2/T1-weighted?

Teng Yi Huang, Ing Jye Huang, Cheng Yu Chen, Klaus Scheffler, Hsiao Wen Chung, Hui Cheng Cheng

Research output: Contribution to journalArticle

41 Citations (Scopus)

Abstract

Images acquired using the TrueFISP technique (true fast imaging with steady-state precession) are generally believed to exhibit T2/T1-weighting. In this study, it is demonstrated that with the widely used half-flip-angle preparation scheme, approaching the steady state requires a time length comparable to the scan time such that the transient-state response may dominate the TrueFISP image contrast. Two-dimensional images of the human brain were obtained using various phase-encoding matrices to investigate the transient-state signal behavior. Contrast between gray and white matter was found to change significantly from proton-density- to T2/T1-weighted as the phase-encoding matrix size increased, which was in good agreement with theoretical predictions. It is concluded that TrueFISP images in general exhibit T2/T1-contrast, but should be more appropriately regarded as exhibiting a transient-state combination of proton-density and T2/T1 contrast under particular imaging conditions. Interpretation of tissue characteristics from TrueFISP images in clinical practice thus needs to be exercised with caution.

Original languageEnglish
Pages (from-to)684-688
Number of pages5
JournalMagnetic Resonance in Medicine
Volume48
Issue number4
DOIs
Publication statusPublished - Oct 1 2002
Externally publishedYes

Fingerprint

Protons
Brain
White Matter
Gray Matter

Keywords

  • Gray/white matter contrast
  • Steady-state free precession
  • Transient state
  • TrueFISP

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Huang, T. Y., Huang, I. J., Chen, C. Y., Scheffler, K., Chung, H. W., & Cheng, H. C. (2002). Are trueFISP images T2/T1-weighted? Magnetic Resonance in Medicine, 48(4), 684-688. https://doi.org/10.1002/mrm.10260

Are trueFISP images T2/T1-weighted? / Huang, Teng Yi; Huang, Ing Jye; Chen, Cheng Yu; Scheffler, Klaus; Chung, Hsiao Wen; Cheng, Hui Cheng.

In: Magnetic Resonance in Medicine, Vol. 48, No. 4, 01.10.2002, p. 684-688.

Research output: Contribution to journalArticle

Huang, TY, Huang, IJ, Chen, CY, Scheffler, K, Chung, HW & Cheng, HC 2002, 'Are trueFISP images T2/T1-weighted?', Magnetic Resonance in Medicine, vol. 48, no. 4, pp. 684-688. https://doi.org/10.1002/mrm.10260
Huang TY, Huang IJ, Chen CY, Scheffler K, Chung HW, Cheng HC. Are trueFISP images T2/T1-weighted? Magnetic Resonance in Medicine. 2002 Oct 1;48(4):684-688. https://doi.org/10.1002/mrm.10260
Huang, Teng Yi ; Huang, Ing Jye ; Chen, Cheng Yu ; Scheffler, Klaus ; Chung, Hsiao Wen ; Cheng, Hui Cheng. / Are trueFISP images T2/T1-weighted?. In: Magnetic Resonance in Medicine. 2002 ; Vol. 48, No. 4. pp. 684-688.
@article{924810c3e7f242c68d58f67c6f780a85,
title = "Are trueFISP images T2/T1-weighted?",
abstract = "Images acquired using the TrueFISP technique (true fast imaging with steady-state precession) are generally believed to exhibit T2/T1-weighting. In this study, it is demonstrated that with the widely used half-flip-angle preparation scheme, approaching the steady state requires a time length comparable to the scan time such that the transient-state response may dominate the TrueFISP image contrast. Two-dimensional images of the human brain were obtained using various phase-encoding matrices to investigate the transient-state signal behavior. Contrast between gray and white matter was found to change significantly from proton-density- to T2/T1-weighted as the phase-encoding matrix size increased, which was in good agreement with theoretical predictions. It is concluded that TrueFISP images in general exhibit T2/T1-contrast, but should be more appropriately regarded as exhibiting a transient-state combination of proton-density and T2/T1 contrast under particular imaging conditions. Interpretation of tissue characteristics from TrueFISP images in clinical practice thus needs to be exercised with caution.",
keywords = "Gray/white matter contrast, Steady-state free precession, Transient state, TrueFISP",
author = "Huang, {Teng Yi} and Huang, {Ing Jye} and Chen, {Cheng Yu} and Klaus Scheffler and Chung, {Hsiao Wen} and Cheng, {Hui Cheng}",
year = "2002",
month = "10",
day = "1",
doi = "10.1002/mrm.10260",
language = "English",
volume = "48",
pages = "684--688",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

TY - JOUR

T1 - Are trueFISP images T2/T1-weighted?

AU - Huang, Teng Yi

AU - Huang, Ing Jye

AU - Chen, Cheng Yu

AU - Scheffler, Klaus

AU - Chung, Hsiao Wen

AU - Cheng, Hui Cheng

PY - 2002/10/1

Y1 - 2002/10/1

N2 - Images acquired using the TrueFISP technique (true fast imaging with steady-state precession) are generally believed to exhibit T2/T1-weighting. In this study, it is demonstrated that with the widely used half-flip-angle preparation scheme, approaching the steady state requires a time length comparable to the scan time such that the transient-state response may dominate the TrueFISP image contrast. Two-dimensional images of the human brain were obtained using various phase-encoding matrices to investigate the transient-state signal behavior. Contrast between gray and white matter was found to change significantly from proton-density- to T2/T1-weighted as the phase-encoding matrix size increased, which was in good agreement with theoretical predictions. It is concluded that TrueFISP images in general exhibit T2/T1-contrast, but should be more appropriately regarded as exhibiting a transient-state combination of proton-density and T2/T1 contrast under particular imaging conditions. Interpretation of tissue characteristics from TrueFISP images in clinical practice thus needs to be exercised with caution.

AB - Images acquired using the TrueFISP technique (true fast imaging with steady-state precession) are generally believed to exhibit T2/T1-weighting. In this study, it is demonstrated that with the widely used half-flip-angle preparation scheme, approaching the steady state requires a time length comparable to the scan time such that the transient-state response may dominate the TrueFISP image contrast. Two-dimensional images of the human brain were obtained using various phase-encoding matrices to investigate the transient-state signal behavior. Contrast between gray and white matter was found to change significantly from proton-density- to T2/T1-weighted as the phase-encoding matrix size increased, which was in good agreement with theoretical predictions. It is concluded that TrueFISP images in general exhibit T2/T1-contrast, but should be more appropriately regarded as exhibiting a transient-state combination of proton-density and T2/T1 contrast under particular imaging conditions. Interpretation of tissue characteristics from TrueFISP images in clinical practice thus needs to be exercised with caution.

KW - Gray/white matter contrast

KW - Steady-state free precession

KW - Transient state

KW - TrueFISP

UR - http://www.scopus.com/inward/record.url?scp=0036771645&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036771645&partnerID=8YFLogxK

U2 - 10.1002/mrm.10260

DO - 10.1002/mrm.10260

M3 - Article

C2 - 12353286

AN - SCOPUS:0036771645

VL - 48

SP - 684

EP - 688

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 4

ER -