An intelligent data encoding algorithm to control high voltage multiplexers for multi-channel medical ultrasound applications is validated in this paper. The time interleaving scanning sequence is controlled spatially on the ultrasound transducer elements to avoid the strong interference caused by the excitation of neighbor elements. The output noise of multiplexer which is designed to enable 32-channel ultrasound scanner mapped with a 128-element linear probe is measured to quantify the interference. The experimental results have shown the leakage at the outputs of multiplexer due to the excitation of neighboring elements is negligible by adoption of the proposed encoding scheme.

Original languageEnglish
Title of host publicationDigest of Technical Papers - IEEE International Conference on Consumer Electronics
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1-2
Number of pages2
ISBN (Electronic)9781479938308
DOIs
Publication statusPublished - Sep 18 2014
Externally publishedYes
Event1st IEEE International Conference on Consumer Electronics - Taiwan, ICCE-TW 2014 - Taipei, Taiwan
Duration: May 26 2014May 28 2014

Conference

Conference1st IEEE International Conference on Consumer Electronics - Taiwan, ICCE-TW 2014
CountryTaiwan
CityTaipei
Period5/26/145/28/14

Fingerprint

Acoustic noise
Ultrasonics
Transducers
Scanning
Electric potential

ASJC Scopus subject areas

  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Liou, J. C., Hsia, C., & Lee, P. L. (2014). An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound. In Digest of Technical Papers - IEEE International Conference on Consumer Electronics (pp. 1-2). [6904003] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICCE-TW.2014.6904003

An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound. / Liou, Jian Chiun; Hsia, Chin; Lee, Po Lei.

Digest of Technical Papers - IEEE International Conference on Consumer Electronics. Institute of Electrical and Electronics Engineers Inc., 2014. p. 1-2 6904003.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Liou, JC, Hsia, C & Lee, PL 2014, An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound. in Digest of Technical Papers - IEEE International Conference on Consumer Electronics., 6904003, Institute of Electrical and Electronics Engineers Inc., pp. 1-2, 1st IEEE International Conference on Consumer Electronics - Taiwan, ICCE-TW 2014, Taipei, Taiwan, 5/26/14. https://doi.org/10.1109/ICCE-TW.2014.6904003
Liou JC, Hsia C, Lee PL. An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound. In Digest of Technical Papers - IEEE International Conference on Consumer Electronics. Institute of Electrical and Electronics Engineers Inc. 2014. p. 1-2. 6904003 https://doi.org/10.1109/ICCE-TW.2014.6904003
Liou, Jian Chiun ; Hsia, Chin ; Lee, Po Lei. / An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound. Digest of Technical Papers - IEEE International Conference on Consumer Electronics. Institute of Electrical and Electronics Engineers Inc., 2014. pp. 1-2
@inproceedings{fb3ec7959c744638a342e3ab8598b783,
title = "An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound",
abstract = "An intelligent data encoding algorithm to control high voltage multiplexers for multi-channel medical ultrasound applications is validated in this paper. The time interleaving scanning sequence is controlled spatially on the ultrasound transducer elements to avoid the strong interference caused by the excitation of neighbor elements. The output noise of multiplexer which is designed to enable 32-channel ultrasound scanner mapped with a 128-element linear probe is measured to quantify the interference. The experimental results have shown the leakage at the outputs of multiplexer due to the excitation of neighboring elements is negligible by adoption of the proposed encoding scheme.",
author = "Liou, {Jian Chiun} and Chin Hsia and Lee, {Po Lei}",
year = "2014",
month = "9",
day = "18",
doi = "10.1109/ICCE-TW.2014.6904003",
language = "English",
pages = "1--2",
booktitle = "Digest of Technical Papers - IEEE International Conference on Consumer Electronics",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - An intelligence data encoding algorithm for low noise interference multi-channel medical ultrasound

AU - Liou, Jian Chiun

AU - Hsia, Chin

AU - Lee, Po Lei

PY - 2014/9/18

Y1 - 2014/9/18

N2 - An intelligent data encoding algorithm to control high voltage multiplexers for multi-channel medical ultrasound applications is validated in this paper. The time interleaving scanning sequence is controlled spatially on the ultrasound transducer elements to avoid the strong interference caused by the excitation of neighbor elements. The output noise of multiplexer which is designed to enable 32-channel ultrasound scanner mapped with a 128-element linear probe is measured to quantify the interference. The experimental results have shown the leakage at the outputs of multiplexer due to the excitation of neighboring elements is negligible by adoption of the proposed encoding scheme.

AB - An intelligent data encoding algorithm to control high voltage multiplexers for multi-channel medical ultrasound applications is validated in this paper. The time interleaving scanning sequence is controlled spatially on the ultrasound transducer elements to avoid the strong interference caused by the excitation of neighbor elements. The output noise of multiplexer which is designed to enable 32-channel ultrasound scanner mapped with a 128-element linear probe is measured to quantify the interference. The experimental results have shown the leakage at the outputs of multiplexer due to the excitation of neighboring elements is negligible by adoption of the proposed encoding scheme.

UR - http://www.scopus.com/inward/record.url?scp=84907803043&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84907803043&partnerID=8YFLogxK

U2 - 10.1109/ICCE-TW.2014.6904003

DO - 10.1109/ICCE-TW.2014.6904003

M3 - Conference contribution

AN - SCOPUS:84907803043

SP - 1

EP - 2

BT - Digest of Technical Papers - IEEE International Conference on Consumer Electronics

PB - Institute of Electrical and Electronics Engineers Inc.

ER -